Added Rockfibre Insulated DPC to your list of saved products. View saved products

Open State Cavity Barrier

Open State Cavity Barrier Open State Cavity Barrier Open State Cavity Barrier Open State Cavity Barrier
Fire product

ARC Open State Cavity Barrier

Open State Cavity Barrier for ventilated cavities

  • Reactive intumescent element
  • Either 60min or 120min fire integrity
  • 25mm or 44mm air gap for ventilated cavity
  • Tested for ASFP TGD19 standards
  • Fixing brackets included as standard
  • Suitable for use horizontally
  • Third party certificated by IFC

Description

ARC Open State Cavity Barriers (OSCB) are designed for installation within cavities where ventilation is required in service use. Manufactured from non-combustible rockfibre mineral wool with a reactive intumescent layer, the cavity barrier can provide an air gap of up to either 25mm or 44mm.

The intumescent layer will rapidly expand when exposed to heat in a fire event, closing off the air gap and preventing vertical fire spread within the external wall cavity.

Suitable for installation horizontally, ARC Open State Cavity Barriers should be partnered with ARC Fire Stop Slab installed vertically for a complete cavity barrier solution.

Key stats

OSCB25

Cavity widths available 100 – 450mmm
Third Party Certification IFC Certification number: IFCC 1935
Max. air gap 25mm
Colour Red with green strip
Fire performance: Integrity 60 mins
Fire performance: Insulation 60 mins
Dimensions Depth : Cavity width less 25mm - Thickness: 82mm - Length: 1200mm
Fixing method ARC OSCB Fixing Bracket

OSCBPLUS25

Cavity widths available 100 - 300mm
Third Party Certification IFC Certification number: IFCC 1935
Max. air gap 25mm
Colour Red with blue strip
Fire performance: Integrity 120 mins
Fire performance: Insulation 120 mins
Dimensions Depth : Cavity width less 25mm - Thickness: 82mm - Length: 1200mm
Fixing method ARC OSCB Fixing Bracket

OSCB44

Cavity widths available 100 – 300mm
Third Party Certification IFC Certification number: IFCC 1935
Max. air gap 44mm
Colour Red with yellow strip
Fire performance; Integrity 60 mins
Fire performance: Insulation 60 mins
Dimensions Depth : Cavity width less 44mm - Thickness: 82mm - Length: 1200mm
Fixing method ARC OSCB Fixing Bracket only

Notes: see separate fixing details for specific bracket specification relevant to cavity width and barrier type.

Please contact us for requirements outside of these ranges. Non standard details, sizes and test data may be available.

Other products you may be interested in

Fire product

Fire Stop Slab

ARC Fire Stop Slab provides up to two hours fire integrity horizontally or vertically within external masonry walls, ideal for use at separating floor levels.

Product details
Cavity Stop Sock

Fire product

Cavity Stop Sock

ARC Cavity Stop Sock restricts the spread of smoke and flames within the cavity of external masonry walls.

Product details
ARC Eco-Closer offering insulation at a window junction

Fire product

Eco-Closer

ARC Eco-Closer closes the cavity around window and door openings in masonry walls, providing up to 60 minutes fire integrity.

Product details
ARC rockfibre insulated DPC providing fire stopping insulation in a masonry structure.

Fire product

Rockfibre Insulated DPC

ARC Rockfibre Insulated DPC is a fire rated cavity closer designed to close the cavity around window and door reveals in conjunction with a return block, fitting between the return block and inner edge of the outer skin of brickwork.

Product details